Series 240/241 Instruction Manual Table of Contents
IM-24-A 0-1
Sierra Series 240 and 241
Innova-Mass™ Multi-Parameter
Vortex Mass Flow Meters
Models 240-VT, 240-VTP, 241-VT, 241-VTP
Instruction Manual
Part Number IM-24X, Rev. A 1/07
5 Harris Court, Building L, Monterey, CA 93940
(831) 373-0200 (800) 866-0200 Fax: (831) 373-4402
http://www.sierrainstruments.com
Sierra Instruments b.v. Bolstoen 30A 1046 AV Amsterdam The Netherlands
+31(0) 20-6145810 Fax +31 (0) 20-6145815
IMPORTANT: This manual is for use with 240/241 Vortex Products
purchased February 2007 or later
Przeglądanie stron 0
1 2 3 4 5 6 ... 77 78

Podsumowanie treści

Strona 1 - IM-24-A 0-1

Series 240/241 Instruction Manual Table of Contents IM-24-A 0-1 Sierra Series 240 and 241 Innova-Mass™ Multi-Parameter Vortex Mass Flow Meters

Strona 2 - Customer Notice

Chapter 1 Introduction Series 240/241 Instruction Manual 1-4 IM-24-A Vortex Shedding Frequency Von Karman vortices form downstream of a shedder bar

Strona 3 - Table of Contents

Series 240/241 Instruction Manual Chapter 1 Introduction IM-24-A 1-5 Re = ρ V D μ St = f d V Flow Velocity Range To ensure trouble-free oper

Strona 4 - Appendix B Glossary

Chapter 1 Introduction Series 240/241 Instruction Manual 1-6 IM-24-A As shown in Figure 1-3, Innova-Mass™ meters exhibit a constant Strouhal number

Strona 5 - Figures

Series 240/241 Instruction Manual Chapter 1 Introduction IM-24-A 1-7 Pressure Measurement Innova-Mass Flow Meters incorporate a solid-state pressure

Strona 6 - Warnings and Cautions

Chapter 1 Introduction Series 240/241 Instruction Manual 1-8 IM-24-A Flow Meter Electronics Innova-Mass Flow Meter electronics are available mounted

Strona 7 - Chapter 1 Introduction

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-1 Chapter 2 Installation Installation Overview Sierra’s Innova-Mass Vortex Flow

Strona 8 - Technical Assistance

Chapter 2 Installation Series 240/241 Instruction Manual 2-2 IM-24-A Unobstructed Flow Requirements Select an installation site that will minimize p

Strona 9 - Velocity Measurement

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-3 Series 240 In-Line Flow Meter Installation Install the Series 240 In-Line Flow

Strona 10

Chapter 2 Installation Series 240/241 Instruction Manual 2-4 IM-24-A Wafer-Style Flow Meter Installation Install the wafer-style meter between two c

Strona 11 - 2

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-5 Flange-Style Flow Meter Installation Install the flange-style meter between two

Strona 12 - Temperature Measurement

Table of Contents Series 240/241 Instruction Manual 0-2 IM-24-A Customer Notice Unless you have specifically ordered Sierra’s optional O2 cleaning,

Strona 13 - Flow Meter Configurations

Chapter 2 Installation Series 240/241 Instruction Manual 2-6 IM-24-A Series 241 Insertion Flow Meter Installation Prepare the pipeline for installa

Strona 14 - Flow Meter Electronics

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-7 Cold Tap Guidelines Refer to a standard code for all pipe tapping operations. T

Strona 15 - Chapter 2 Installation

Chapter 2 Installation Series 240/241 Instruction Manual 2-8 IM-24-A Hot Tap Guidelines Refer to a standard code for all pipe tapping operations. Th

Strona 16

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-9 Flow Meter Insertion The sensor head must be properly positioned in the pipe.

Strona 17 - 4-bolt 8-bolt 12-bolt

Chapter 2 Installation Series 240/241 Instruction Manual 2-10 IM-24-A Installing Flow Meters with a Compression Connection* Use the following formul

Strona 18

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-11 Insertion Procedure for Meters with a Compression Connection Figure 2-7. Fl

Strona 19

Chapter 2 Installation Series 240/241 Instruction Manual 2-12 IM-24-A Installing Flow Meters with a Packing Gland Connection* Use the formula below

Strona 20 - Isolation Valve Requirements

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-13 Insertion Procedure for Flow Meters with Permanent Insertion Tool Figure 2-9

Strona 21 - Cold Tap Guidelines

Chapter 2 Installation Series 240/241 Instruction Manual 2-14 IM-24-A Insertion Procedure for Flow Meters with Removable Insertion Tool Figure 2-1

Strona 22 - Hot Tap Guidelines

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-15 7. Tighten the packing gland nuts to stop leakage around the stem. Do not tor

Strona 23 - Flow Meter Insertion

Series 240/241 Instruction Manual Table of Contents IM-24-A 0-3 Table of Contents Chapter 1 Introduction Innova-Mass™ Vortex Mass Flow Meters ...

Strona 24

Chapter 2 Installation Series 240/241 Instruction Manual 2-16 IM-24-A Insertion Procedure for Flow Meters with No Insertion Tool (Packing Gland Conn

Strona 25

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-17 Adjusting Meter Orientation Depending on installation requirements, you may ne

Strona 26

Chapter 2 Installation Series 240/241 Instruction Manual 2-18 IM-24-A Enclosure Adjustment (Series 240 Only) Figure 2-13. Enclosure Viewing Adjust

Strona 27

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-19 Wiring Connections The NEMA 4X enclosure contains an integral wiring compartme

Strona 28

Chapter 2 Installation Series 240/241 Instruction Manual 2-20 IM-24-A 4-20 mA Output Connections The standard Innova-Mass Flow Meter has a single 4-

Strona 29 - Example:

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-21 Figure 2-18. Non-Isolated 4–20 mA Output Using Meter Input Power Supply Fi

Strona 30 - (Packing Gland Connection)

Chapter 2 Installation Series 240/241 Instruction Manual 2-22 IM-24-A Figure 2-20. Isolated Pulse Output with External Power Supply Figure 2-21

Strona 31 - Adjusting Meter Orientation

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-23 Alarm Output Connections One alarm output (Alarm 1) is included on the standar

Strona 32 - 18 IM-24-A

Chapter 2 Installation Series 240/241 Instruction Manual 2-24 IM-24-A Figure 2-24. Isolated Alarm Output Using Meter Provided Power Supply Remote E

Strona 33 - Wiring Connections

Series 240/241 Instruction Manual Chapter 2 Installation IM-24-A 2-25 Optional Input Electronics Wiring The meter has two optional input wiring t

Strona 34 - 4-20 mA Output Connections

Table of Contents Series 240/241 Instruction Manual 0-4 IM-24-A Fluid Menu ...

Strona 35 - Pulse Output Connections

Series M22/M23 Instruction Manual Chapter 3 Operation IM-22, IM-23 3-1 Chapter 3 Operating Instructions After installing the Innova-Mass Vortex Fl

Strona 36

Chapter 3 Operation Series M22/M23 Instruction Manual 3-2 IM-22, IM-23 Start-Up To begin flow meter operation: 1. Verify the flow meter is install

Strona 37 - Alarm Output Connections

Series M22/M23 Instruction Manual Chapter 3 Operation IM-22, IM-23 3-3 Using the Setup Menus Programming the Flow Meter 1. Enter the Setup Menu

Strona 38 - Remote Electronics Wiring

Chapter 3 Operation Series M22/M23 Instruction Manual 3-4 IM-22, IM-23 Output Menu

Strona 39 - R = 1000 ohm

Series M22/M23 Instruction Manual Chapter 3 Operation IM-22, IM-23 3-5 Example for Setting an Output The following shows how to set Output 1 to meas

Strona 40 - Flow Meter Display/Keypad

Chapter 3 Operation Series M22/M23 Instruction Manual 3-6 IM-22, IM-23 Display Menu PasswordENTERUsekeys to access menusDisplayMenuCycle Time(Sec)0

Strona 41 - Start-Up

Series M22/M23 Instruction Manual Chapter 3 Operation IM-22, IM-23 3-7 Alarms Menu Example for Setting an Alarm The following shows how to set Ala

Strona 42 - Using the Setup Menus

Chapter 3 Operation Series M22/M23 Instruction Manual 3-8 IM-22, IM-23 Totalizer #1 Menu PasswordENTERUsekeys to access menusTotalizerMenuTotaling

Strona 43 - Output Menu

Series M22/M23 Instruction Manual Chapter 3 Operation IM-22, IM-23 3-9 Totalizer #2 Menu PasswordENTERUsekeys to access menusTotalizerMenuTotaling

Strona 44 - IM-22, IM-23 3-5

Chapter 3 Operation Series 240/241 Instruction Manual 3-2 IM-24-A Energy Menu – For EMS Energy Meters Only Configuration: There are several pos

Strona 45 - Display Menu

Series 240/241 Instruction Manual Table of Contents IM-24-A 0-5 Figures 1-1. In-Line Vortex Multi-Parameter Mass Flow Meter ... 1-3 1

Strona 46 - Alarms Menu

Series 240/241 Instruction Manual Chapter 3 Operation IM-24-A 3-3 Fluid Menu Password ENTER Usekeys to access menusFluid Menu Flowing Fluid Liquids

Strona 47 - Totalizer #1 Menu

Chapter 3 Operation Series 240/241 Instruction Manual 3-4 IM-24-A Units Menu Use the Units Menu to configure the flow meter with the desired units

Strona 48 - Totalizer #2 Menu

Series 240/241 Instruction Manual Chapter 3 Operation IM-24-A 3-5 Time & Date Menu PasswordENTERUsekeys to access menusTime & DateMenuSet T

Strona 49

Chapter 3 Operation Series 240/241 Instruction Manual 3-6 IM-24-A Diagnostics Menu Use the Diagnostics Menu to simulate operation and review the

Strona 50 - Fluid Menu

Series 240/241 Instruction Manual Chapter 3 Operation IM-24-A 3-7 Calibration Menu The Calibration Menu contains the calibration coefficients for

Strona 51 - Units Menu

Chapter 3 Operation Series 240/241 Instruction Manual 3-8 IM-24-A Password Menu PasswordENTERUsekeys to access menusPasswordMenuSet Password1234ENT

Strona 52 - Time & Date Menu

Series 240/241 Instruction Manual Chapter 4 Troubleshooting & Repair IM-22/IM-23 4-1 Chapter 4 Troubleshooting and Repair Hidden Diagnostics M

Strona 53 - Diagnostics Menu

Chapter 4 Troubleshooting & Repair Series 240/241 Instruction Manual 4-2 IM-22/IM-23 Column One Hidden Diagnostics Values • f = vortex sheddin

Strona 54 - Calibration Menu

Series 240/241 Instruction Manual Chapter 4 Troubleshooting & Repair IM-22/IM-23 4-3 • Adj. Flilter = adjustable filter. Displays the filterin

Strona 55 - Password Menu

Chapter 4 Troubleshooting & Repair Series 240/241 Instruction Manual 4-4 IM-22/IM-23 low alarm on the output. When High is selected it will giv

Strona 56 - Energy EMS Meters

Table of Contents Series 240/241 Instruction Manual 0-6 IM-24-A Warnings and Cautions Warning! Agency approval for hazardous location installatio

Strona 57

Series 240/241 Instruction Manual Chapter 4 Troubleshooting & Repair IM-22/IM-23 4-5 o Slope = unique value for each set of electronics. o Int

Strona 58

Chapter 4 Troubleshooting & Repair Series 240/241 Instruction Manual 4-6 IM-22/IM-23 2. Mechanical installation may be incorrect. Verify the

Strona 59 - 4-4 IM-22/IM-23

Series 240/241 Instruction Manual Chapter 4 Troubleshooting & Repair IM-22/IM-23 4-7 vortex sensor from the analog board (the analog board is th

Strona 60 - IM-22/IM-23 4-5

Chapter 4 Troubleshooting & Repair Series 240/241 Instruction Manual 4-8 IM-22/IM-23 1. For remote mounted electronics, carefully check all the

Strona 61 - 4-6 IM-22/IM-23

Series 240/241 Instruction Manual Chapter 4 Troubleshooting & Repair IM-22/IM-23 4-9 tronics stack in the enclosure. Loosen these screws (Note:

Strona 62 - IM-22/IM-23 4-7

Chapter 4 Troubleshooting & Repair Series 240/241 Instruction Manual 4-10 IM-22/IM-23 Returning Equipment to the Factory Before returning any P

Strona 63 - 4-8 IM-22/IM-23

Series 240/241 Instruction Manual Appendix A Specifications IM-24-A A-1 Appendix A Product Specifications Accuracy Process Variables 240 Series I

Strona 64 - IM-22/IM-23 4-9

Appendix A Specifications Series 240/241 Instruction Manual A-2 IM-24-A Nominal Pipe Size (in)Pressure0.50.7511.5234681.8 3 5 13 22 50 87 198 34718

Strona 65 - 4-10 IM-22/IM-23

Series 240/241 Instruction Manual Appendix A Specifications IM-24-A A-3 Nominal Pipe Size (in)Pressure0.50.7511.5234686.5 12 20 49 82 183 318 722 12

Strona 66 - IM-24-A A-1

Appendix A Specifications Series 240/241 Instruction Manual A-4 IM-24-A 241 Pressure Ratings Probe Seal Process Connection Material Rating Orderin

Strona 67 - A-2 IM-24-A

Series 240/241 Instruction Manual Chapter 1 Introduction IM-24-A 1-1 Chapter 1 Introduction Innova-Mass™ Multi-Parameter Vortex Mass Flow Meters Th

Strona 68 - IM-24-A A-3

Series 240/241 Instruction Manual Appendix A Specifications IM-24-A A-5 Pocess Fluid and Process Fluid: Ambient Temperature Standard temperature

Strona 69 - A-4 IM-24-A

Series 240/241 Instruction Manual Appendix B Glossary IM-24-A B-1 Er Appendix B Glossary A B C D A Cross sectional area. ACFM Actual Cubic Fe

Strona 70 - IM-24-A A-5

Appendix B Glossary Series 240/241 Instruction Manual B-2 IM-24-A I J K L In-Line Flow Meter A flow meter which includes a short section of pipi

Strona 71 - E F G H

Series 240/241 Instruction Manual Appendix B Glossary IM-24-A B-3 Q R S T Q Flow rate, usually volumetric. Rangeability Highest measurable flo

Strona 72 - M N O P

Series 240/241 Instruction Manual Appendix C Fluid Calculations IM-24-A C-1 Appendix C Fluid Calculations Calculations for Steam T & P When “St

Strona 73 - U V W X Y Z

Appendix C Fluid Calculations Series 240/241 Instruction Manual C-2 IM-24-A Calculations for Gas (“Real Gas” and “Other Gas”) Use this formula to de

Strona 74 - 102697.121828.0)(

Series 240/241 Instruction Manual Appendix C Fluid Calculations IM-24-A C-3 Calculations for Liquid Use this formula to determine the settings for “

Strona 75

Series 240/241 Instruction Manual Appendix D HART Commands IM-24-A D-1 Appendix D HART Commands with DD Menu

Strona 76 - Calculations for Liquid

Appendix D HART Commands Series 240/241 Instruction Manual D-2 IM-24-A Appendix D HART Commands without DD Menu Online Menu1 Device Setup2 PV3 PV

Strona 77 - IM-24-A D-1

Chapter 1 Introduction Series 240/241 Instruction Manual 1-2 IM-24-A Note and Safety Information We use note, caution and warning statements through

Strona 78 - D-2 IM-24-A

Series 240/241 Instruction Manual Chapter 1 Introduction IM-24-A 1-3 How the Innova-Mass Vortex Mass Flow Meter Operates Figure 1-1. In-Line Vorte