Sierra S5020 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Systemy kontroli dostępu bezpieczeństwa Sierra S5020. Installation Instructions - Duplex Plusz Biztonságtechnika Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Instructions

InstallationInstructionsModel S5832SGControl Panel8 to 32 Zones

Strona 2 - Table of Contents

6The REMM also has five independently programmable re-lays. The relay programming options are explained in theprogramming summary, Block 7.The AUX ter

Strona 3

7Digital Communicator ConnectionsRemoving/Installing the Digital CommunicatorThe digital communicator plugs into the control panel PCBand is secured b

Strona 4 - Sierra Accessory Loading

8Direct ConnectEnabledDirect ConnectDisabledFigure 15Direct Connect using the S5070SG Digital Communicator4. Enable the Direct Connect jumper (see Fig

Strona 5 - S5832SG Terminal Layout

9Programming With an LED KeypadYou may use an LED keypad to program the control panel.The LED display on the keypad is used to display all pro-grammin

Strona 6 - 3.15"

10Once a valid installer code has been entered, the installerhas the option of using either the Quick or Menu Program-ming mode to enter data into the

Strona 7 - AC Power

11Installer Mode Options, (Block 0)There are 10 Installer Mode Options which are availablefrom the Menu mode. These options allow the installer to tes

Strona 8 - Keypad Wiring

12To enter a Message or Label, use the following key com-mands:Key Function[2] Scroll forward through characters/symbols[8] Scroll backward through ch

Strona 9 - Accessories

Maid Code Enable (by Area)Cmd Loc 009 010 011 012 013 014 015 016Default 0 0 0 0 0 0 0 0Area

Strona 10 - S5058 Zone Expansion Module

14Options:0 Limited Functions**1 Disarm2 Arm4 Bypass8 Open/Close Rpt16 Lang. Code opt. 132 Lang. Code opt. 2CommentsThese programming Options determin

Strona 11 - SN961 SpreadNet Keyfob

15Options:1 250 mS2 500 mSCommentsThese Options select the zone response time (in mil-liseconds) of zones 1 - 8 and zones available fromthe S5058 Zone

Strona 13 - Block # (steady)

16CommentsIf enabled, press and hold any of the soft zone keys for twoseconds to report an alarm condition (see also Block 4, CL148 (Report Routing)).

Strona 14 - Menu Programming Mode

17CommentsIf enabled, the keypad buzzer sounds during the exit delay.The keypad buzzer rate is faster during the last 10 secondsof the exit delay.Keyp

Strona 15 - Event Memory

18CommentsLimits the number of alarm signals reported and/or annunciated during anarmed period. Additional alarms will not be indicated. Setting the l

Strona 16 - Figure 25

19CommentsIf enabled, this option disables the strobe/siren, to extendbackup time with a low battery condition.Strobe/Siren Disable with Low BatteryCm

Strona 17

20CommentsThese locations are Reserved for Future Use and are not available in thisfirmware version.CommentsIf enabled, supplies voltage to external b

Strona 18

21Account #1Cmd Loc 005 006 007 008 009 010Default 000000Range 0 - 15 0 - 15 0 - 15 0 - 15 0 - 15 0 - 15Receiver Type (Receiver #2)Cmd Loc 003Default

Strona 19

22Telephone Number (RPS Callback)Cmd Loc 085 086 087 088 089 090 091 092Cmd Loc 093 094 095 096 097 098 099 100Default 14 (All Locations)Range 0 - 15

Strona 20

23CommentsThe selected outputs will sound for three sec-onds following a successful closing report.Ringback Outputs EnableCmd Loc 115Default 0Range 0

Strona 21

24Installer Programming Report RoutingCmd Loc 155Default 2Range 1 - 5CommentsReport routing for installer programming startand end reports (see Block

Strona 22

25Report Code, Alarm (Zones 1 - 32)Cmd Loc 001 002 003 004 005 006 007 008 009 010 011 012Default 01 01 0 1 01 01 01Zone 1 2 3 4

Strona 23

Compliance and Regulatory Information ...iInstalling and Connecting the Control Panel ... 1 - 5Sierra S5832SG PC Board Layout...

Strona 24

26Block 5 - Reporting Digits Programming (cont.)CommentsThis is the code sent to the central station when the user enters a duresscode. (See Block 3,

Strona 25

27CommentsThese two-digit codes are sent when the system detects a primary orsecondary phone line cut, or their respective restorals. When using singl

Strona 26

28Block 5 - Reporting Digits Programming (cont.)Report Code, Ground FaultCmd Loc 159 160Default 0 0Range 0 - 15 (All CL)Report Code, Ground Fault Res

Strona 27

29CommentsThese two-digit report codes indicate tamper, trouble, and restoral con-ditions associated with hardwired keypads. When using single-digitre

Strona 28

30Block 6 - Real Time Clock ProgrammingThe Real Time Clock Programming Block is divided into two sections and has a total of 9 Command Locations (CL 0

Strona 29

31Block 7 - Auxiliary Devices ProgrammingThe Auxiliary Devices Programming Block has a total of 79 Command Locations (CL 001 - 079). Each of the first

Strona 30

32CommentsIf enabled, jumps to the last 5 seconds of the exit delay,then arms the system. Requires a normally open switchconnected to keypad (TXD and

Strona 31

33Timer Units (REMM #2, Relay #1)Cmd Loc 025Default 2Range 1 - 5Timer Count (REMM #2, Relay #1)Cmd Loc 026Default 30Range 1 - 255CommentsFor REMM #2,

Strona 32

34CommentsThese Options will determine the Day(s) ofthe Week and Time of Day when the pro-grammed relay will automatically close. Thevalue programmed

Strona 33

35Block 8 - SpreadNet ProgrammingThe SpreadNet Programming Block has a total of 45 Command Locations (CL 001 - 045). The SpreadNet transmittersmust be

Strona 34

iCountry Specific Compliance InformationSingaporeThe following hardware and programming guidelines are requiredfor installation of this system in Sing

Strona 35

36Area Access by User Number (User # 1 - 60)Cmd Loc 034 035 036 037 038 039 040 041User # 1 2 3 4 5 6 7 8Cmd Loc 042 043 044 045 046 0

Strona 36

37Area Access (SN Keyfob/Remote # 1 - 60)Cmd Loc 119 120 121 122 123 124 125 126User # 1 2 3 4 5 6 7 8Cmd Loc 127 128 129 130 131 132

Strona 37

38User Codes (cont.)Cmd Loc 085 086 087 088User #22 0 0 0 0Cmd Loc 089 090 091 092User #23 0 0 0 0Cmd Loc 093 094 095 096User #24 0 0 0 0Cmd Loc 097 0

Strona 38

39User Codes (cont.)Cmd Loc 213 214 215 216User #54 0 0 0 0Cmd Loc 217 218 219 220User #55 0 0 0 0Cmd Loc 221 222 223 224User #56 0 0 0 0Cmd Loc 225 2

Strona 39

C & K is a registered trademark of C & K ComponentsSierra and SpreadNet are registered trademarks of C & K Systems, Inc.All other trademar

Strona 40

1S5832SG Terminal LayoutIntroductionThis manual contains basic information and program-ming information for the Sierra Model S5832SG con-trol panel.Fo

Strona 41

2Housing Mounting HolesHousing Mounting HolesWiring Knock-outsWiring Knock-outsFigure 3 (a)Mounting the S5832SEnclosure266 mm10.5"261 mm10.25&quo

Strona 42 - Comments

3Backup BatteryThe system employs one or more 6.5 AH (Model 1265) or 7.0AH (Model 1270) sealed lead-acid storage battery. Connectthe battery to the co

Strona 43

4Output TerminalsTable 3 shows the Output Terminals of the S5832SG, withthe Voltage and Current Range of each Output. The Tablealso shows the maximum

Strona 44

5Keypad AddressingThe S5832SG control panel will support up to 16 hardwiredkeypads. Each keypad must have a different address, withaddresses ranging f

Komentarze do niniejszej Instrukcji

Brak uwag